ZO BC Replace 1-existing CTOF with new ones.Replace 2-existing paint mix rooms with new ones.
Dallas building permits
Data through Oct 26, 2026Source: Dallas OpenData: Building Permits
Dallas in the last 30 days
- Permits issued
- 4,956
- Newest Permit
- Oct 26, 2026
- Plumbing1378
- Electrical1037
- HVAC655
- Remodel624
- New construction366
- 75229323
- 75214260
- 75230211
- 75248201
- 75217199
- ALEJANDRO COMPIAN R.M.P9
- ABLE CRAFT GENERAL CONTRACTOR LLC1
- HCBeck, LTD1
- SPRING VALLEY CONSTRUCTION CO.1
Permits
4,956 Permits in the last 30 days, page 76 of 100
Pro shows every Permit back to Jan 1, 2024. Full history
ZO BC Replace existing 2 Drive Through Paint Booths with new ones.Replace existing 4 Paint mix rooms with new ones.
Front and rear carport detached addition - Front 1,153 SQFT and Rear 1500 SQFT
MCR Lobby -Capital Improvement - Commercial Interior Remodel of Level 1 & 2 Lobby with New Stair
3525 Turtle Creek 3D - Interior remodel to include widening door at hall to match foyer/living, remove fireplace and surrounding wall, widen doorway from bedroom to bath, other cosmetic work including electrical & plumbing fixtures
MCR 2nd Floor Restrooms - Commercial Interior Remodel - 456 SF
2999 Turtle Creek -These are partitions walls that will be removed at end of show Create 2 new spaces in existing interior for upcoming annual design show. Only framing and electric is needed. Space 20 = 100'Space 21 = 100'
Interior demo for suite 950
QTEAM INHOUSE Cath 5 Room Remodel: Equipment Replacement - MEP / StructuralLEVEL 2 ALTERATION (AREA OF RENOVATION IS LESS THAN 50% OF THE OVERALL AREA OF THE EXISTING BUILDING)
Interior remodel of an existing 1,619 SF personal service / massage establishment. construct five new treatment rooms using non-load-bearing interior partitions. each room will be provided with two electrical receptacles and one wall mounted light fixture. relocate the existing restroom to the adjacent room and install connections for a washer and dryer. existing land use and occupancy to remain unchanged. No building expansion and no change of use.
ZO BC HE WE WERE ADVISED TO APPLY FOR FINISH OUT PERMIT BECAUSE OF A PREVIOUS WHITE BOX APPLICATION. THERE WAS A FIRE THAT EFFECTED THE MIDDLE SECTION AND THOSE WALLS WERE REMOVED AND NEVER REPLACED. THE EXISTING WALLS WERE ALWAYS THERE. PLEASE EVALUATE THIS APPLICATION WITH CO-26-004440.
QTEAM INHOUSE - Interior finish out of existing one story building.
BU ZO Remove three (3) interior walls located in the entrance/reception area. No electrical wiring or electrical components will be affected by the removal of these walls. Work will be limited to the removal of the specified interior walls and associated materials.
BU ZO EL PL ME HE General Contractor hired to complete interior remodel projectContinuation of expired permit: 2203211023_170014962-003New Trades will validate under new permit.
ZO BC DAYCARE THE SPANISH IMMERSION SCH RENOVATION OF EXISTING LIBRARY TO HOUSE SPANISH IMMERSION DAYCARE FOR CHILDREN. THIS . ADDITON OF EXTERIOR ACCESS FROM CLASSROOMS TO BACKYARD. ADD REQUIRED RESTROOMS.
installing an iron fence for the front with a sliding gate, then the sides and back are a metal panel fence 8 feet tall
MCR 355 Linear feet of concrete retaining wall
Replacing an old wood plank fenceFabricate & Install Steel Fence with Steel Mesh 64' LF of fencing with one 36" wide gate w/9foot height.One 9' LF section w/ 9' height.Material to consist of 2" square tubing, 14 gauge, with 3/16" welded wire mesh on a picture frame constructed from 2" x 3/8" flat bar steel.Fencing to be fabricated in roughly 12' sections/assemblies. Actual section lengths may vary as required for the installation. Panel assembly heights may vary slightly due to the existing slope of the ground after installation. Panels will be installed in a step a down style to follow the grade.Fence will have a black powder coat finish.
Installation of approximately 300LF OF 6' Wrought iron steel privacy fence black.
MCR W/BATTERY Install 11.48kw PV system with 28 modules & 1 battery.
Roof-mounted photovoltaic solar system with 8 new 405W modules, 3.240 kW DC, 11.500 kW AC inverter, and 15.06 kWh battery storage.
MCR W/BATTERY Installation of a Grid Tied, Roof Mounted, Solar PV systems, with sonnen home 11 batteries
MCR W/BATTERY Residential Addition - Solar Rooftop, backup battery, and MPU/MPR
-Remove and Replace Existing Roof asphalt shingles with a new 30 year shingles and synthetic paper
Follow-on work
- GuttersRule reroof-gutters v1
Remove current underlayment and shingles. Install new synthetic underlayment and 30 year architectural shingles.
Follow-on work
- GuttersRule reroof-gutters v1
Reroof - Shingle only - OC Duration TruDef Storm in Estate Gray
Follow-on work
- GuttersRule reroof-gutters v1
remove and replace roof
Follow-on work
- GuttersRule reroof-gutters v1
Tear off existing roof and install a composition shingle roof. Remove and replace damaged decking where needed.
Follow-on work
- GuttersRule reroof-gutters v1
Tear off existing shingles and replace with Owens Corning Duration Storm in Driftwood.
Follow-on work
- GuttersRule reroof-gutters v1
Remove & replace shingles
Follow-on work
- GuttersRule reroof-gutters v1
Remove existing shingles and replace with new shingles.
Follow-on work
- GuttersRule reroof-gutters v1
Remove existing asphalt shingles and install new asphalt shingles. Installing Atlas Pinnacle Pristine - Weathered Shadow TopShield CraftGrade W20 Synthetic Underlayment and TopShield G300 Ice & Water Shield valley protection
Follow-on work
- GuttersRule reroof-gutters v1
Reroof with composite shingles; no decking; tearoff only - owens corning oakridge trudef
Follow-on work
- GuttersRule reroof-gutters v1
Removing old roof and replacing with new roof
Follow-on work
- GuttersRule reroof-gutters v1
Rerrof - Shingle only - OC Duration Storm in Onyx Black
Follow-on work
- GuttersRule reroof-gutters v1
Remove old roof and replace with a new shingle roof system
Follow-on work
- GuttersRule reroof-gutters v1
removing old shingles n felt installing new shingles n felt and ice n water barrier on valleys and new drip edge
Follow-on work
- GuttersRule reroof-gutters v1
MCR Residential Remodel: Installation of a pre-fabricated, semi-recessed residential tank pool on an existing residential lot. The pool package utilizes factory-engineered components manufactured by Contain Water Systems Inc. and is assembled and installed onsite by StainlessSwim, LLC. The structure consists of a continuous 4-inch pitch by 1/2-inch depth corrugated galvanized steel wall panel system (G130 galvanization rating) secured with SAE Grade 8.5 electro-galvanized hardware. The containment system features a dual-layer liner layout: a 40 oz. black geotextile floor pre-liner and a minimum 40 mil thick reinforced flexible membrane main liner certified to NSF-61 / ANSI standards, fastened via an unpenetrated compression-fit securement clip grid. The pool measures 9 feet in diameter with a uniform 4-foot depth, resting on a leveled foundation base and featuring an exterior liquid rubber structural coating for semi-inground moisture protection.Scope of work includes:1. Site preparation, clearance, and utility tracking (via 811 verification) for a partial in-ground, semi-recessed installation footprint.2. Mechanical assembly of factory pre-punched G130 corrugated steel walls, structural wall brackets, and anchor clips.3. Preparation of the level foundation floor base, installation of the 40 oz. geotextile foundation pre-liner, and placement of the NSF-61 certified 40 mil main liner.4. Application of a protective exterior liquid rubber coating to all semi-submerged external tank walls.5. Setup of a mechanical filtration pad, pool ladder, and associated circulation accessories.6. Electrical equipotential bonding loop grid conforming to NEC Article 680 regulations clamped directly to the conductive galvanized steel shell.7. Execution of all final electrical, mechanical grounding, and plumbing connections by Texas-licensed trade professionals pulling separate trade permits linked under this Master Building Permit.8. Maintenance of a code-compliant, continuous safety barrier consisting of a 48-inch high perimeter fence with self-closing, self-latching, outward-swinging gates.
Follow-on work
- FenceRule pool-barrier v1
replace whole kitchen drain & sewer line, 5 ft tunnel
New drain line for two full bathrooms. One washer machine, one kitchen sink, and new gas line inside the home and outside the yard.
New Build - Plumbing associated with permit #RES-NEW-26-001372
Gas test for meter release. Gas provider requesting city approval.
Added bathroom
New yard gas service, gas test
New Building Associated with permit #RES-NEW-26-001686
slab leak and clean out replacement Install 1" automatic shut-off main valve by installing components, securing fittings, and testing for leaks and proper operation.
Gas pressure test post repair
Excavate tunnel 5ft
replace building under house under pier and beam repair sewer in yard
Plumbing Remodel
| Issue date | Permit type | Address | ZIP | Declared value | Description | Contractor name as published | Follow-on work | Contact |
|---|---|---|---|---|---|---|---|---|
| Oct 7, 2026 | Remodel | 6206 PEELER ST | 75235 | No value stated | ZO BC Replace 1-existing CTOF with new ones.Replace 2-existing paint mix rooms with new ones. | |||
| Oct 7, 2026 | Remodel | 3331 HAGGAR WAY | 75235 | No value stated | ZO BC Replace existing 2 Drive Through Paint Booths with new ones.Replace existing 4 Paint mix rooms with new ones. | |||
| Oct 7, 2026 | Remodel | 2939 S ERVAY ST | 75215 | No value stated | Front and rear carport detached addition - Front 1,153 SQFT and Rear 1500 SQFT | |||
| Oct 7, 2026 | Remodel | 13727 NOEL RD | 75240 | No value stated | MCR Lobby -Capital Improvement - Commercial Interior Remodel of Level 1 & 2 Lobby with New Stair | |||
| Oct 7, 2026 | Remodel | 3525 TURTLE CREEK BLVD | 75219 | No value stated | 3525 Turtle Creek 3D - Interior remodel to include widening door at hall to match foyer/living, remove fireplace and surrounding wall, widen doorway from bedroom to bath, other cosmetic work including electrical & plumbing fixtures | |||
| Oct 7, 2026 | Remodel | 13727 NOEL RD | 75240 | No value stated | MCR 2nd Floor Restrooms - Commercial Interior Remodel - 456 SF | |||
| Oct 7, 2026 | Remodel | 2999 TURTLE CREEK BLVD | 75219 | No value stated | 2999 Turtle Creek -These are partitions walls that will be removed at end of show Create 2 new spaces in existing interior for upcoming annual design show. Only framing and electric is needed. Space 20 = 100'Space 21 = 100' | |||
| Oct 7, 2026 | Remodel | 2323 VICTORY AVE | 75219 | No value stated | Interior demo for suite 950 | |||
| Oct 7, 2026 | Remodel | 621 N HALL ST | 75226 | No value stated | QTEAM INHOUSE Cath 5 Room Remodel: Equipment Replacement - MEP / StructuralLEVEL 2 ALTERATION (AREA OF RENOVATION IS LESS THAN 50% OF THE OVERALL AREA OF THE EXISTING BUILDING) | |||
| Oct 7, 2026 | Remodel | 6780 ABRAMS RD | 75231 | No value stated | Interior remodel of an existing 1,619 SF personal service / massage establishment. construct five new treatment rooms using non-load-bearing interior partitions. each room will be provided with two electrical receptacles and one wall mounted light fixture. relocate the existing restroom to the adjacent room and install connections for a washer and dryer. existing land use and occupancy to remain unchanged. No building expansion and no change of use. | |||
| Oct 7, 2026 | Remodel | 9016 GARLAND RD | 75218 | No value stated | ZO BC HE WE WERE ADVISED TO APPLY FOR FINISH OUT PERMIT BECAUSE OF A PREVIOUS WHITE BOX APPLICATION. THERE WAS A FIRE THAT EFFECTED THE MIDDLE SECTION AND THOSE WALLS WERE REMOVED AND NEVER REPLACED. THE EXISTING WALLS WERE ALWAYS THERE. PLEASE EVALUATE THIS APPLICATION WITH CO-26-004440. | |||
| Oct 7, 2026 | Remodel | 3417 GASTON AVE | 75246 | No value stated | QTEAM INHOUSE - Interior finish out of existing one story building. | |||
| Oct 7, 2026 | Remodel | 11053 ABLES LN | 75229 | No value stated | BU ZO Remove three (3) interior walls located in the entrance/reception area. No electrical wiring or electrical components will be affected by the removal of these walls. Work will be limited to the removal of the specified interior walls and associated materials. | |||
| Oct 7, 2026 | Remodel | 2540 ELM ST | 75226 | No value stated | BU ZO EL PL ME HE General Contractor hired to complete interior remodel projectContinuation of expired permit: 2203211023_170014962-003New Trades will validate under new permit. | |||
| Oct 7, 2026 | Remodel | 5707 SKILLMAN ST | 75206 | No value stated | ZO BC DAYCARE THE SPANISH IMMERSION SCH RENOVATION OF EXISTING LIBRARY TO HOUSE SPANISH IMMERSION DAYCARE FOR CHILDREN. THIS . ADDITON OF EXTERIOR ACCESS FROM CLASSROOMS TO BACKYARD. ADD REQUIRED RESTROOMS. | |||
| Oct 7, 2026 | Commercial Accessory Structure Permit | 3217 HALIFAX ST | 75247 | No value stated | installing an iron fence for the front with a sliding gate, then the sides and back are a metal panel fence 8 feet tall | |||
| Oct 7, 2026 | Commercial Accessory Structure Permit | 8405 MANDERVILLE LN | 75231 | No value stated | MCR 355 Linear feet of concrete retaining wall | |||
| Oct 7, 2026 | Commercial Accessory Structure Permit | 508 PARK AVE | 75201 | No value stated | Replacing an old wood plank fenceFabricate & Install Steel Fence with Steel Mesh 64' LF of fencing with one 36" wide gate w/9foot height.One 9' LF section w/ 9' height.Material to consist of 2" square tubing, 14 gauge, with 3/16" welded wire mesh on a picture frame constructed from 2" x 3/8" flat bar steel.Fencing to be fabricated in roughly 12' sections/assemblies. Actual section lengths may vary as required for the installation. Panel assembly heights may vary slightly due to the existing slope of the ground after installation. Panels will be installed in a step a down style to follow the grade.Fence will have a black powder coat finish. | |||
| Oct 7, 2026 | Commercial Accessory Structure Permit | 2380 W NORTHWEST HWY | 75220 | No value stated | Installation of approximately 300LF OF 6' Wrought iron steel privacy fence black. | |||
| Oct 6, 2026 | Solar | 704 FERN CREEK DR | 75253 | No value stated | MCR W/BATTERY Install 11.48kw PV system with 28 modules & 1 battery. | |||
| Oct 6, 2026 | Solar | 7636 TEXRIDGE DR | 75232 | No value stated | Roof-mounted photovoltaic solar system with 8 new 405W modules, 3.240 kW DC, 11.500 kW AC inverter, and 15.06 kWh battery storage. | |||
| Oct 6, 2026 | Solar | 10214 SWEET GUM ST | 75249 | No value stated | MCR W/BATTERY Installation of a Grid Tied, Roof Mounted, Solar PV systems, with sonnen home 11 batteries | |||
| Oct 6, 2026 | Solar | 4331 BONNIE VIEW RD | 75216 | No value stated | MCR W/BATTERY Residential Addition - Solar Rooftop, backup battery, and MPU/MPR | |||
| Oct 6, 2026 | Roofing | 6752 SHADOW CREEK DR | 75241 | No value stated | -Remove and Replace Existing Roof asphalt shingles with a new 30 year shingles and synthetic paper |
| ||
| Oct 6, 2026 | Roofing | 10825 WATERBRIDGE CIR | 75218 | No value stated | Remove current underlayment and shingles. Install new synthetic underlayment and 30 year architectural shingles. |
| ||
| Oct 6, 2026 | Roofing | 7126 ARAGLIN CT | 75230 | No value stated | Reroof - Shingle only - OC Duration TruDef Storm in Estate Gray |
| ||
| Oct 6, 2026 | Roofing | 10111 SHADOW WAY | 75243 | No value stated | remove and replace roof |
| ||
| Oct 6, 2026 | Roofing | 2725 MAVERICK AVE | 75228 | No value stated | Tear off existing roof and install a composition shingle roof. Remove and replace damaged decking where needed. |
| ||
| Oct 6, 2026 | Roofing | 6938 LLOYD VALLEY LN | 75230 | No value stated | Tear off existing shingles and replace with Owens Corning Duration Storm in Driftwood. |
| ||
| Oct 6, 2026 | Roofing | 6716 SANTA MARIA LN | 75214 | No value stated | Remove & replace shingles |
| ||
| Oct 6, 2026 | Roofing | 10306 ESTATE LN | 75238 | No value stated | Remove existing shingles and replace with new shingles. |
| ||
| Oct 6, 2026 | Roofing | 5915 LEWISBURG LN | 75236 | No value stated | Remove existing asphalt shingles and install new asphalt shingles. Installing Atlas Pinnacle Pristine - Weathered Shadow TopShield CraftGrade W20 Synthetic Underlayment and TopShield G300 Ice & Water Shield valley protection |
| ||
| Oct 6, 2026 | Roofing | 1163 TIMPLEMORE DR | 75218 | No value stated | Reroof with composite shingles; no decking; tearoff only - owens corning oakridge trudef |
| ||
| Oct 6, 2026 | Roofing | 2522 CATHERINE ST | 75211 | No value stated | Removing old roof and replacing with new roof |
| ||
| Oct 6, 2026 | Roofing | 1607 CASCADE AVE | 75224 | No value stated | Rerrof - Shingle only - OC Duration Storm in Onyx Black |
| ||
| Oct 6, 2026 | Roofing | 5777 PRESTWICK LN | 75252 | No value stated | Remove old roof and replace with a new shingle roof system |
| ||
| Oct 6, 2026 | Roofing | 5830 WINDING WOODS TRL | 75227 | No value stated | removing old shingles n felt installing new shingles n felt and ice n water barrier on valleys and new drip edge |
| ||
| Oct 6, 2026 | Pool | 7923 ENCLAVE WAY | 75218 | No value stated | MCR Residential Remodel: Installation of a pre-fabricated, semi-recessed residential tank pool on an existing residential lot. The pool package utilizes factory-engineered components manufactured by Contain Water Systems Inc. and is assembled and installed onsite by StainlessSwim, LLC. The structure consists of a continuous 4-inch pitch by 1/2-inch depth corrugated galvanized steel wall panel system (G130 galvanization rating) secured with SAE Grade 8.5 electro-galvanized hardware. The containment system features a dual-layer liner layout: a 40 oz. black geotextile floor pre-liner and a minimum 40 mil thick reinforced flexible membrane main liner certified to NSF-61 / ANSI standards, fastened via an unpenetrated compression-fit securement clip grid. The pool measures 9 feet in diameter with a uniform 4-foot depth, resting on a leveled foundation base and featuring an exterior liquid rubber structural coating for semi-inground moisture protection.Scope of work includes:1. Site preparation, clearance, and utility tracking (via 811 verification) for a partial in-ground, semi-recessed installation footprint.2. Mechanical assembly of factory pre-punched G130 corrugated steel walls, structural wall brackets, and anchor clips.3. Preparation of the level foundation floor base, installation of the 40 oz. geotextile foundation pre-liner, and placement of the NSF-61 certified 40 mil main liner.4. Application of a protective exterior liquid rubber coating to all semi-submerged external tank walls.5. Setup of a mechanical filtration pad, pool ladder, and associated circulation accessories.6. Electrical equipotential bonding loop grid conforming to NEC Article 680 regulations clamped directly to the conductive galvanized steel shell.7. Execution of all final electrical, mechanical grounding, and plumbing connections by Texas-licensed trade professionals pulling separate trade permits linked under this Master Building Permit.8. Maintenance of a code-compliant, continuous safety barrier consisting of a 48-inch high perimeter fence with self-closing, self-latching, outward-swinging gates. |
| ||
| Oct 6, 2026 | Plumbing | 3543 TIMBERVIEW RD | 75229 | No value stated | replace whole kitchen drain & sewer line, 5 ft tunnel | |||
| Oct 6, 2026 | Plumbing | 2850 TOLUCA AVE | 75224 | No value stated | New drain line for two full bathrooms. One washer machine, one kitchen sink, and new gas line inside the home and outside the yard. | |||
| Oct 6, 2026 | Plumbing | 1625 BANNOCK AVE | 75215 | No value stated | New Build - Plumbing associated with permit #RES-NEW-26-001372 | |||
| Oct 6, 2026 | Plumbing | 640 S BELT LINE RD | 75253 | No value stated | Gas test for meter release. Gas provider requesting city approval. | |||
| Oct 6, 2026 | Plumbing | 6009 OAKCREST RD | 75248 | No value stated | Added bathroom | |||
| Oct 6, 2026 | Plumbing | 5050 PERSHING ST | 75206 | No value stated | New yard gas service, gas test | |||
| Oct 6, 2026 | Plumbing | 3643 BICKERS ST | 75212 | No value stated | New Building Associated with permit #RES-NEW-26-001686 | |||
| Oct 6, 2026 | Plumbing | 6911 HICKORY CREEK LN | 75252 | No value stated | slab leak and clean out replacement Install 1" automatic shut-off main valve by installing components, securing fittings, and testing for leaks and proper operation. | |||
| Oct 6, 2026 | Plumbing | 3119 MAYHEW DR | 75228 | No value stated | Gas pressure test post repair | |||
| Oct 6, 2026 | Plumbing | 6017 TIMBER CREEK LN | 75248 | No value stated | Excavate tunnel 5ft | |||
| Oct 6, 2026 | Plumbing | 155 BON AIRE DR | 75218 | No value stated | replace building under house under pier and beam repair sewer in yard | |||
| Oct 6, 2026 | Plumbing | 6257 CHESLEY LN | 75214 | No value stated | Plumbing Remodel |