Replace existing fence with 8' board on board cedar fence
propose fence, infront of the house itll be hard iron of 4' height and the other half of the house will be 8' height of wood fence
adding a fence, 8 feet
Mechanically attach 1/2" EPS Fanfold cover board and .60mil TPO Single ply membrane over existing roof (1 layer). No tear off and no change to pitch.
Follow-on work
- GuttersRule reroof-gutters v1
Demo (1) sink and cap in the wall.
COMMERCIAL INTERIOR REMODEL
COMMERCIAL INTERIOR REMODEL
Replacement of 3/4" Watts 009 RPZ at Lakewood Country Club's Golf Cart Barn.
Plumbing Trade Inspections
RPZ for dishwasher
Plumbing
Plumbing
Gas repair with test for meter release
gas test
Sewer spot repair
PLUMBING PERMIT FOR METER NO OTHER WORK BEING DONE
GAS RELEASE 3 AC 1 FIREPLACE
GAS LEAK AT THE POOL AREA
Follow-on work
- FenceRule pool-barrier v1
REPLACE 1" RPZ AT POOL
Follow-on work
- FenceRule pool-barrier v1
REPLACE THE 2" DBL CHECK VALVE BY BLDG 3
gas test
Annual gas test
1-8 unitStandard Review: New construction - fourplex - IRC project
1-8 unit-Standard Review: New Construction - fourplex - IRC project
QTEAM INHOUSE - first time finish out for office tenant
HVAC DUCTING
install 5 RTUs, curbs, humid sensors, 55 GRDs, 2 VAV accutherm diff, 48 start collars, 3 round inline damper, 1 rect inline damper, 7 circ fans, 4 gas fired htr, 2 air curtain, fyre wrap, kitchen hoods, 3 roof mntd exhaust fans, 2 inline transfer fans
HVAC REMODEL
COMMERCIAL INTERIOR REMODEL
COMMERCIAL INTERIOR REMODEL
COMMERCIAL INTERIOR REMODEL
installation of one 6x5 type 2 vent hood & one 5x4 type 1 with duct work
Install new HVAC in amenity area
Full electrical re-wire ,service upgrade
ELECTRICAL REMODEL
No need electricity connection
Electrical for restrooms, replace light fixtures
Pulling damaged wire in the main switchgear room from basement to Oncor transformer
Needing a Electrical Service Release no work Permit
Small academy renovation. They are adding in a stage within the multipurpose room, updating light fixtures to LED.
BU ZO Change out two light pole fixtures to LED lights. Change out7 perimeter light fixtures on building to LED lights. Add 1 new lightpole base and light pole. All light fixtures are standard lightscurrently. We will be switching all lights to LED lights. Light pole thatis being added is in the island in the parking lot and traffic will notbe affected.
installing lights, installing cover plats in open junction box locations, installing switch leg at locations
COMMERCIAL INTERIOR REMODEL
COMMERCIAL INTERIOR REMODEL
REPLACE MAIN BREAKER
BLD 27 Emergency permit; building has no power and residents have been without power since 9/10/26Electrical repair/ reattached service to wall
install exterior disconnect with transocket
Remove and replace 200amp service disconnect due to burned lug and wire on line side. Will need power turned off to make reapir.
Install a 200amp 3 phase overhead service, the meter and service disconnect will be mounted on the exterior and the main panel will be inside the building. Customer wants general power installed, which would be basic lighting. 20 receptacles, 16 light fixtures, and 10 wallpacks around the exterior.
| Issue date | Permit type | Address | ZIP | Declared value | Description | Contractor name as published | Follow-on work | Contact |
|---|---|---|---|---|---|---|---|---|
| Oct 2, 2026 | Residential Accessory Structure Permit | 5555 GOODWIN AVE | 75206 | No value stated | Fence Permit Application for a single-family residential property. | |||
| Oct 2, 2026 | Residential Accessory Structure Permit | 5518 KEMPER CT | 75220 | No value stated | Replace existing fence with 8' board on board cedar fence | |||
| Oct 2, 2026 | Residential Accessory Structure Permit | 2927 JEROME ST | 75223 | No value stated | propose fence, infront of the house itll be hard iron of 4' height and the other half of the house will be 8' height of wood fence | |||
| Oct 2, 2026 | Residential Accessory Structure Permit | 1910 DENNISON ST | 75212 | No value stated | adding a fence, 8 feet | |||
| Oct 2, 2026 | Roofing | 5301 ALPHA RD | 75240 | No value stated | Mechanically attach 1/2" EPS Fanfold cover board and .60mil TPO Single ply membrane over existing roof (1 layer). No tear off and no change to pitch. |
| ||
| Oct 2, 2026 | Plumbing | 3000 PEGASUS PARK DR | 75247 | No value stated | Demo (1) sink and cap in the wall. | |||
| Oct 2, 2026 | Plumbing | 3102 OAK LAWN AVE | 75219 | No value stated | COMMERCIAL INTERIOR REMODEL | |||
| Oct 2, 2026 | Plumbing | 2053 W NORTHWEST HWY | 75220 | No value stated | COMMERCIAL INTERIOR REMODEL | |||
| Oct 2, 2026 | Plumbing | 1912 ABRAMS RD | 75214 | No value stated | Replacement of 3/4" Watts 009 RPZ at Lakewood Country Club's Golf Cart Barn. | |||
| Oct 2, 2026 | Plumbing | 3826 ROSS AVE | 75204 | No value stated | Plumbing Trade Inspections | |||
| Oct 2, 2026 | Plumbing | 8190 PARK LN | 75231 | No value stated | RPZ for dishwasher | |||
| Oct 2, 2026 | Plumbing | 3020 PEGASUS PARK DR | 75247 | No value stated | Plumbing | |||
| Oct 2, 2026 | Plumbing | 3826 ROSS AVE | 75204 | No value stated | Plumbing | |||
| Oct 2, 2026 | Plumbing | 3661 E KIEST BLVD | 75203 | No value stated | Gas repair with test for meter release | |||
| Oct 2, 2026 | Plumbing | 2815 PEAVY RD | 75228 | No value stated | gas test | |||
| Oct 2, 2026 | Plumbing | 4830 LAKAWANA ST | 75247 | No value stated | Sewer spot repair | |||
| Oct 2, 2026 | Plumbing | 6060 N CENTRAL EXPY | 75206 | No value stated | PLUMBING PERMIT FOR METER NO OTHER WORK BEING DONE | |||
| Oct 2, 2026 | Plumbing | 1111 DRAGON ST | 75207 | No value stated | GAS RELEASE 3 AC 1 FIREPLACE | |||
| Oct 2, 2026 | Plumbing | 14145 NOEL RD | 75254 | No value stated | GAS LEAK AT THE POOL AREA |
| ||
| Oct 2, 2026 | Plumbing | 4755 GRAMERCY OAKS DR | 75287 | No value stated | REPLACE 1" RPZ AT POOL |
| ||
| Oct 2, 2026 | Plumbing | 4755 GRAMERCY OAKS DR | 75287 | No value stated | REPLACE THE 2" DBL CHECK VALVE BY BLDG 3 | |||
| Oct 2, 2026 | Plumbing | 7777 FOREST LN | 75230 | No value stated | gas test | |||
| Oct 2, 2026 | Plumbing | 4242 OFFICE PKWY | 75204 | No value stated | Annual gas test | |||
| Oct 2, 2026 | New construction | 2726 ELSIE FAYE HEGGINS ST | 75215 | No value stated | 1-8 unitStandard Review: New construction - fourplex - IRC project | |||
| Oct 2, 2026 | New construction | 2718 ELSIE FAYE HEGGINS ST | 75215 | No value stated | 1-8 unit-Standard Review: New Construction - fourplex - IRC project | |||
| Oct 2, 2026 | New construction | 2200 N HENDERSON AVE | 75206 | No value stated | QTEAM INHOUSE - first time finish out for office tenant | |||
| Oct 2, 2026 | HVAC | 4555 TRAVIS ST | 75205 | No value stated | HVAC DUCTING | |||
| Oct 2, 2026 | HVAC | 14897 PRESTON RD | 75254 | No value stated | install 5 RTUs, curbs, humid sensors, 55 GRDs, 2 VAV accutherm diff, 48 start collars, 3 round inline damper, 1 rect inline damper, 7 circ fans, 4 gas fired htr, 2 air curtain, fyre wrap, kitchen hoods, 3 roof mntd exhaust fans, 2 inline transfer fans | |||
| Oct 2, 2026 | HVAC | 3000 PEGASUS PARK DR | 75247 | No value stated | HVAC REMODEL | |||
| Oct 2, 2026 | HVAC | 3102 OAK LAWN AVE | 75219 | No value stated | COMMERCIAL INTERIOR REMODEL | |||
| Oct 2, 2026 | HVAC | 2053 W NORTHWEST HWY | 75220 | No value stated | COMMERCIAL INTERIOR REMODEL | |||
| Oct 2, 2026 | HVAC | 3303 LEE PKWY | 75219 | No value stated | COMMERCIAL INTERIOR REMODEL | |||
| Oct 2, 2026 | HVAC | 10110 ROYAL LN | 75238 | No value stated | installation of one 6x5 type 2 vent hood & one 5x4 type 1 with duct work | |||
| Oct 2, 2026 | HVAC | 8099 WALNUT HILL LN | 75231 | No value stated | Install new HVAC in amenity area | |||
| Oct 2, 2026 | Electrical | 605 W MOCKINGBIRD LN | 75247 | No value stated | Full electrical re-wire ,service upgrade | |||
| Oct 2, 2026 | Electrical | 5165 S BUCKNER BLVD | 75227 | No value stated | ELECTRICAL REMODEL | |||
| Oct 2, 2026 | Electrical | 1807 GALLAGHER ST | 75212 | No value stated | No need electricity connection | |||
| Oct 2, 2026 | Electrical | 3237 W NORTHWEST HWY | 75220 | No value stated | Electrical for restrooms, replace light fixtures | |||
| Oct 2, 2026 | Electrical | 3890 W NORTHWEST HWY | 75220 | No value stated | Pulling damaged wire in the main switchgear room from basement to Oncor transformer | |||
| Oct 2, 2026 | Electrical | 9131 S CENTRAL EXPY | 75241 | No value stated | Needing a Electrical Service Release no work Permit | |||
| Oct 2, 2026 | Electrical | 9407 MIDWAY RD | 75220 | No value stated | Small academy renovation. They are adding in a stage within the multipurpose room, updating light fixtures to LED. | |||
| Oct 2, 2026 | Electrical | 12821 PRESTON RD | 75230 | No value stated | BU ZO Change out two light pole fixtures to LED lights. Change out7 perimeter light fixtures on building to LED lights. Add 1 new lightpole base and light pole. All light fixtures are standard lightscurrently. We will be switching all lights to LED lights. Light pole thatis being added is in the island in the parking lot and traffic will notbe affected. | |||
| Oct 2, 2026 | Electrical | 3001 AL LIPSCOMB WAY | 75215 | No value stated | installing lights, installing cover plats in open junction box locations, installing switch leg at locations | |||
| Oct 2, 2026 | Electrical | 3102 OAK LAWN AVE | 75219 | No value stated | COMMERCIAL INTERIOR REMODEL | |||
| Oct 2, 2026 | Electrical | 2053 W NORTHWEST HWY | 75220 | No value stated | COMMERCIAL INTERIOR REMODEL | |||
| Oct 2, 2026 | Electrical | 2217 N FITZHUGH AVE | 75204 | No value stated | REPLACE MAIN BREAKER | |||
| Oct 2, 2026 | Electrical | 7229 FERGUSON RD | 75228 | No value stated | BLD 27 Emergency permit; building has no power and residents have been without power since 9/10/26Electrical repair/ reattached service to wall | |||
| Oct 2, 2026 | Electrical | 10823 SANDEN DR | 75238 | No value stated | install exterior disconnect with transocket | |||
| Oct 2, 2026 | Electrical | 8701 PETERBILT AVE | 75241 | No value stated | Remove and replace 200amp service disconnect due to burned lug and wire on line side. Will need power turned off to make reapir. | |||
| Oct 2, 2026 | Electrical | 2630 FERRIS ST | 75226 | No value stated | Install a 200amp 3 phase overhead service, the meter and service disconnect will be mounted on the exterior and the main panel will be inside the building. Customer wants general power installed, which would be basic lighting. 20 receptacles, 16 light fixtures, and 10 wallpacks around the exterior. |